     PCM30 PDH Interface Converters Power
Distribution
SCADA_RTU
 

OTS-622

           
 

Products introduce

  Fiber Optic Multiplexer+PCM SDH Distribution
Frame
Transmission Power Antenna
   
     

   
  OTS-622B Multiplexer offers various types of traffic interfaces such as Fast Ethernet, Ethernet, SDH and PDH with flexible network configurations of linear, ring, multiple rings, etc.
The OTS-622B is also well suited for implementation in customer premises. OTS-622B has been developed as a part of OTS-622B family products. OTS-622B also has the following features:

  •      Conforms to the correlative proposal of ITU-T and relating SDH technical criteria of the country.

  •       Full time slot cross connection functions, having powerful, convenient Add and Drop traffic functions and modes.

  •       Modular system design: the equipment can be configured either TM or ADM mode flexibly.

  •         System configuration for either STM-1 or STM-4, with the methods of easily upgrading and network reconfiguring.

  •         Provides multi-type tributary interfaces, having excellent cost performance ratio.

  •         Perfect network management system; flexible network configuration.

  •         A number of traffic protection modes.

  •         multi-function orderwire telephone system

  •         Excellent electromagnetic compatibility performances (EMC and EMI), and highly efficient heat dispersion.

  •         Well maintained and operated; high reliability

   Pizza box structure and nice appearance.
 
 

 Summary  

   
                         
 

Equipment Characteristics

 
  •    2U-height compact-size designation.

  •    Providing 1008 × 1008 VC12 level or 48 × 48 VC3 level or 16 × 16 VC4 level non-blocking cross connection, supporting unidirectional, bi-directional and broadcasting.

  •     Providing sub-network connection protection, channel protection and 1+1 multiplex section protection.

  •     Applicable for a number of network configurations: point to point, linear, ring, star, tree, multi-ring, ring crossing, etc.

  •     Provides E1, T1, E3, T3, 10Base-T and 10/100 Base-T traffic interfaces.

  •     Provides four extended slots reserving traffics to be extended.

  •     Capacity for interfaces:

  • ·      T1 interface(1.5M): up to 128 channels

  • ·      E1 interface(2M):  up to 128 channels

  • ·      E3 interface(34M): up to 12 channels

  • ·      T3 interface(45M): up to 12 channels

  • ·      10 BASE-T Ethernet interface: up to 32 channels

  • ·      10/100 BASE-T Ethernet interface: up to 16 channels

  • ·      STM-4 Optical interface: up to 4 channels

  • ·      STM-1 Optical interface: up to 10 channels

  •    Either way for the use of traffic: independent or protecting each other among Optical interfaces.

  •    Configurations of complicated SNCP network, such as 600M-150M Multi-Ring, 150M-150M Multi-Ring, etc.

  •    Allows configuring STM-1 system to/from STM-4 system only by replacing interface modules; simply upgrading.

  •    Provides orderwire interface (2-wire interface), with the functions of group calling and selected calling.

  •    One 64 kbit/s V.11/V.24 user data interface per Optical interface.

  •    Provides timing synchronous interface

                2048kbit/s or 2048 kHz external clock

·              2048kbits/s tributary

·              STM-1 and STM-4 timing source inputs

·              2048kbit/s or 2048 kHz/s external timing source output

               SSM function

  •      Provides ECC channel of D1 to D3; Using TCP/IP communication protocol.

  •      Providing F (10 Base-T) and f (RS232) network management interfaces for configuration, alarm, performance, maintenance and security functions of ITU-T definition.

  •      Provides a port for eight Housekeeping Alarms, a port for four Housekeeping Controls, and an Alarm Output interface.

  •      Provides local/remote firmware download: in-service upgrading is available for    easy maintenance.

  •     Allows upgrading hardware configuration data without replacing equipment.

  •     Provides the network management for remote connection via serial interface or LAN, which allows monitoring remote NE.

  •       Supports the following application of fiber transmission:

·            Super Long-Distance (≤80km)

·            Long-Distance (≤50km)

·             Short Distance (≤30km)

  •     Provides fans to disperse heat forcibly, or allows natural heat dispersion without using fans as well; provides the intelligent fans controlling temperature and inspecting their own status to guarantee the equipment running stably.

  •      Flexible structure designing: allows the front access or the rear access by the method of mounting shelves.

 

 
                         
 

Function Description


  

  OPS-622C is
the optical transmission equipment of the new generation with a great capacity, belonging to the SDH series products. Having flexible and reliable cable transmission system with XMS-LE, OPS-622C gives better performances in the information highway.

Following lists the feature of OPS-622C:

  •   When configuring with 622 Mbit/smaximum of 128 PDH 2M low-rate signals  can be inserted to SDH STM-4 high-rate signal directly, enabling the connection between PDH and SDH.

  •   When configuring with 155 Mbit/smaximum 126 PDH 2M low-rate signals can be inserted to SDH STM-1 high-rate signal directly, enabling the connection between PDH and SDH.

  •   Using extended board, signals of different rate can be inserted into STM-1 or STM-4 system directly for transmission.

  •   Modular-type design allows configuring 622M equipment or 155M equipment only by replacing interface modules and adding matrix module.

  •   Configurations of TERM (terminal multiplexing unit) and ADM (add/drop multiplexer) are available by STM-1 or STM4 SDH optical transmission system.

  •   SDH optical transmission system is available for point-to-point, linear, ring or other complicated network combining these three types of networks.

                   OPS-622C provides the necessary physical path for network management.




 
                         
   
       
OTS-622 Technique parameters

   
     If you need use's manual, please telephone us.